Abstract
We analyzed the literature data and existing safety guidelines regarding magnetic resonance imaging (MRI) in
patients with implants.
The review contemplates safety precautions in patients with implantable medical devices (IMD) during MRI. Due
to the increase in the number of such patients, medical personnel should be highly competent in IMD classification
and labeling, possible interactions with magnetic fields, as well as accompanying technical documentation and
catamnesis. As per the best practices, we present recommended algorithms for MRI in patients with IMD.
References
- Results of 2010–2015 / City / Site of Moscow. Availableat:
https://www.mos.ru/city/progress/result/id/health/ (accessed March 28, 2018) (in Russ.).
- Hindricks G., Camm J., Merkely B., Pekka Raatikainen
M.J., Arnar D.O. The EHRA White Book 2017 Tenth
Edition. 2017. Available at: https://www.escardio.org/static_file/Escardio/Subspecialty/EHRA/Publications/Documents/2017/ehra-white-book-2017.pdf (accessed
February 08, 2018).
- Hindricks G., Camm J., Merkely B., Pekka Raatikainen
M.J., Arnar D.O. The current status of cardiac electrophysiology
in ESC member countries. 2016. Available
at: https://www.escardio.org/static_file/Escardio/Subspecialty/EHRA/Publications/Documents/EHRA
White Book 2016. Final WEB Version.pdf (accessed
February 08, 2018).
- Pekka Raatikainen M.J., Arnar D.O., Merkely B., Nielsen
J.C., Hindricks G., Heidbuchel H. et al. A decade of
information on the use of cardiac implantable electronic
devices and interventional electrophysiological procedures
in the European Society of Cardiology countries:
2017 Report from the European Heart Rhythm Association.
Europace. 2017; 19 (suppl. 2): ii1–ii90. DOI: 10.1093/europace/eux258
- Implantation and replacement of pacemakers and elec-trodes in 2013. Available at: https://vnoa.ru/upload/otchet_2013.pdf (accessed March 22, 2018) (in Russ.)
- Demography: Federal State Statistics Service. Availableat: http://www.gks.ru/wps/wcm/connect/rosstat_
main/rosstat/ru/statistics/population/demography/#
(accessed March 22, 2018) (in Russ.)
- Scanning patients with MR conditional implants.
Available at: http://usa.philips.com/healthcare/education-resources/publications/fieldstrength/mri-and-mrconditional-implants (accessed April 02, 2018).
- Keevil S. Safety in magnetic resonance imaging. Med.
Phys. Int. J. 2016; 4 (1): 26–34.
- Kanal E., Barkovich A.J., Bell C., Borgstede J.P., Bradley
W.G., Froelich J.W. et al. ACR guidance document
on MR safe practices: 2013. J. Magn. Reson. Imaging.
2013; 37 (3): 501–30. DOI: 10.1002/jmri.24011
- Safety guidelines for magnetic resonance imaging equipment
in clinical use. 2015. Available at: https://www.gov.uk/
government/uploads/system/uploads/attachment_data/
file/476931/MRI_guidance_2015_-_4-02d1.pdf
(accessed February 06, 2018).
- Park S.-M., Kamondetdacha R., Nyenhuis J.A. Calculation
of MRI-induced heating of an implanted medical
lead wire with an electric field transfer function. J. Magn.
Reson. Imaging. 2007; 26 (5): 1278–85. DOI: 10.1002/jmri.21159
- Shellock F.G. Radiofrequency energy-induced heating during
MR procedures: A review. J. Magn. Reson. Imaging.
2000; 12 (1): 30–6. DOI: 10.1002/1522-2586(200007)12:1
- Hargreaves B.A., Worters P.W., Pauly K.B., Pauly J.M.,
Koch K.M., Gold G.E. Metal-induced artifacts in MRI.
Am. J. Roentgenol. 2011; 197 (3): 547–55. DOI: 10.2214/AJR.11.7364
- Glushko L.A., Bockeria O.L. The devices for electrothe-rapy of the heart, compatible with magnetic resonancetomography. Аnnals of Arrhythmology. 2015; 12 (4):225–33.DOI: 10.15275/annaritmol.2015.3.4
- Shellock F.G., Woods T.O., Crues Iii J.V. MR labeling
information for implants and devices: explanation of terminology.
Radiology. 2009; 253 (1): 26–30. DOI: 10.1148/radiol.2531091030
- MRI Safety Home. Available at: http://www.mrisafety.com/
(accessed February 12, 2018).
- Van der Graaf A.W.M., Bhagirath P., Götte M.J.W. MRI
and cardiac implantable electronic devices; current status
and required safety conditions. Neth. Heart J. 2014;
22 (6): 269–76. DOI: 10.1007/s12471-014-0544-x
- Shinbane J.S., Colletti P.M., Shellock F.G. Magnetic
resonance imaging in patients with cardiac pacemakers:
Era of 'MR Conditional' designs. J. Cardiovasc. Magn.
Reson. 2011; 13 (1): 63. DOI: 10.1186/1532-429X-13-63
- Do D.H., Eyvazian V., Bayoneta A.J., Hu P., Finn J.P.,
Bradfield J.S. et al. Cardiac magnetic resonance imaging
using wideband sequences in patients with nonconditional
cardiac implanted electronic devices. Heart Rhythm.
2018; 15 (2): 218–25. DOI: 10.1016/j.hrthm.2017.10.003
- Bockeria O.L., Akhobekov A.A. Magnetic resonance ima-ging safety in patients with implanted cardiostimulatorsand cardioverters-defibrillators. Аnnals of Arrhythmology.2012; 2: 32–9 (in Russ.)
About the authors
- Kristina A. Sergunova, Head of Technical Monitoring and Quality Assurance Development Department; orcid.org/0000-0002-9596-7278
-
Ekaterina S. Akhmad, Researcher of Technical Monitoring and Quality Assurance Development; orcid.org/0000-0002-8235-9361
-
Aleksey V. Petryaykin, Cand. Med. Sc., Associate Professor, Senior Researcher; orcid.org/0000-0003-1694-4682
-
Stanislav A. Kivasev, Head of Radiology Department; orcid.org/0000-0003-1160-5905
-
Dmitriy S. Semenov, Researcher; orcid.org/0000-0002-4293-2514
-
Yuriy А. Vasil'ev, Senior Researcher, Student; orcid.org/0000-0002-0208-5218
-
Sergey P. Morozov, Dr. Med. Sc., Professor, Director; orcid.org/0000-0001-6545-6170
-
Anton V. Vladzimirskiy, Dr. Med. Sc., Deputy Director for Science; orcid.org/0000-0002-2990-7736
-
Lyudmila A. Nizovtsova, Dr. Med. Sc., Professor, Chief Researcher; orcid.org/0000-0002-9614-4505